Skip to content

ifc: ceiling in pieces takes the area of its first top-face piece (RE-486) - #249

Merged
mahach666 merged 4 commits into
mainfrom
feat/covering-first-piece-area
Nov 16, 2026
Merged

mahach666 merged 4 commits into
mainfrom
feat/covering-first-piece-area

Conversation

@mahach666

Copy link
Copy Markdown
Collaborator

Port rvt-rs RE-486 (#1209, changelog.d/fixed/1209-ceiling-pieces-gross-area.md): where a ceiling has no computed host area, GrossCeilingArea is the piece holding its first top face instead of the whole upper surface.\n\n- Faces grouped by serialized SourceFace/MeshMarker within their geometry node (as SurfaceAreaCurrent groups them); the piece is the group of the first top face in serialized order.\n- Applied only with no sketch area, more than one top piece, and a bottom piece of the same area within 0.1% (the saved-mesh RE-480/RE-486 guard); otherwise the whole upper surface stands as before.\n- Sketch-area and single-piece behavior unchanged (284 BaseQuantities tests green + 3 new CoveringFirstPieceTests).\n\nSource: https://github.com/DrunkOnJava/rvt-rs (RE-486, reports/element-framing/RE-486-ceiling-pieces-first-face-gross-area.md). No Autodesk code.

…-486)

Port rvt-rs RE-486 (#1209): where a ceiling has no computed host area, GrossCeilingArea is the piece holding its first top face (grouped by SourceFace/MeshMarker within its node, bottom piece within 0.1%) instead of the whole upper surface. Sketch area and single-piece behavior unchanged. Tests: CoveringFirstPieceTests; BaseQuantities suites green.
…nected pieces

Review #249: TopSurfaceArea admitted any non-vertical face, so a closed sloped solid classified as pieces and shrank GrossCeilingArea. Require horizontal faces at one height per side. Group faces into connected components by shared vertices instead of serialized SourceFace handles, and search every underside piece for the single same-area counterpart at the top piece footprint. Caller-level regression tests through CoveringQuantitiesCurrent for sloped (whole surface) and two-piece (first piece) solids without a host area.
Recheck #249: with a sloped first top face followed by horizontal pieces, the rule picked the later 100 ft2 part (9.29 m2) instead of keeping the whole 436.80 ft2 (40.58 m2). The piece rule now applies only when the first top face itself is horizontal, per RE-486; otherwise the whole upper surface stays. Caller-level regression test covers sloped-first with later horizontal pieces.
@mahach666
mahach666 merged commit a82105d into main Nov 16, 2026
5 checks passed
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

None yet

Projects

None yet

Development

Successfully merging this pull request may close these issues.