Diff view
5 changes: 5 additions & 0 deletions CHANGELOG.md
Original file line number Diff line number Diff line change
Expand Up @@ -7,6 +7,11 @@ and this project adheres to [Semantic Versioning](https://semver.org/spec/v2.0.0

## [Unreleased]

### Changed

- Leica containers that assign their points to their setups now open as one scan per setup, with the id and the name of the
setup. A container that does not assign its points to its setups still opens as one scan, with a warning.

## [0.1.0] - 2026-11-15

First release.
Expand Down
2 changes: 1 addition & 1 deletion README.md
Original file line number Diff line number Diff line change
Expand Up @@ -38,7 +38,7 @@ The library targets .NET 8 and .NET 10. It is managed code with no dependencies
| ASTM E57 | `.e57` | Points decoded for a defined subset: uncompressed bit-packed streams with single or double precision Cartesian coordinates, 8-bit colour and 8-bit intensity. Pose translation and rotation are applied. Scaled-integer coordinates, spherical coordinates and other codecs are not supported: a scan that uses them lists normally and fails when its points are read. Per-point validity flags and images are not read, so points flagged as invalid are returned as stored, and colour or intensity fields of any other type or range are ignored. Page checksums are verified. |
| ReCap scan | `.rcs` | Experimental. The header is read; point decoding covers only the node layout of major version 3, and any other layout is rejected. Colour and intensity are decoded, and normals when a node has them. `HasColors`, `HasIntensities` and `HasNormals` are fixed for this layout and are not read from the file. |
| ReCap project | `.rcp` | Lists the scans of the project manifest and opens the `.rcs` files it finds next to the project. Node transforms are exposed as data and are not applied to points. |
| Leica scan container | `.lgsx`, `.lgs` | Experimental. Points are decoded from the compressed point blocks: position, and colour, intensity and normals when the block has them. Poses and bounds are not read, all points of a container form one scan (setups are not separated; a warning says so), and the point count is found by decoding the data, which is slow on large files. |
| Leica scan container | `.lgsx`, `.lgs` | Experimental. Points are decoded from the compressed point blocks: position, and colour, intensity and normals when the block has them. When the container assigns its points to its setups, there is one scan per setup, named after the setup; when it does not, all points of the container form one scan and a warning says so. Poses and bounds are not read, and the point count is found by decoding the data, which is slow on large files. |
| FARO scan | `.fls`, or a FARO scan folder | Experimental. The scan grid and angles are read from the stored parameters and points are projected from the range grid; a file without them fails to open. The point count is the grid size, not a count of valid returns. Folder scans are read with an assumed record layout and intensity scale (a warning says so). |
| PinPoint project | `.srf`, `.smf`, or a folder with `ScanProject.json` or `.smf`/`.srf` files | Experimental. The manifest (scan names, ids, poses, counts) is read. Points come from the referenced `.bin` files, in either of two layouts: a table of named channels, or numbered sections with a property table and Snappy-compressed channels, which PclIO decodes itself. Colour, intensity and normals are reported only when the file has that channel; in the second layout only positions, colours and intensities are read, and the per-point flags and grid indices stored beside them are not interpreted, so every stored point that passes the plausibility rule below is returned. A manifest with a scan position list takes the point count from the manifest, else from the data file; a manifest with a data object list always reports 0 because that count is not known. |
| EdgeWise | `.c3db`, `.c3ptx` | Experimental. A `.c3db` point database lists the scan clusters and a `.c3ptx` is one cluster file; the cluster files give positions only. The scale of the cluster positions is not stored in the files, so it is an assumption of the reader and positions are only as exact as it. |
Expand Down
4 changes: 2 additions & 2 deletions docs/public-api.md
Original file line number Diff line number Diff line change
Expand Up @@ -62,7 +62,7 @@ drop points that fail a plausibility rule (see the README), so a scan can yield
| E57 | Declared by the file. It is not checked against the point data until the points are read. |
| ReCap scan | Declared in the header. It is not checked against the node table. |
| ReCap project | Declared by the project manifest; 0 when the manifest states none. |
| Leica | Computed. The container does not store it, so the first access decodes all of the point data and caches the result, which can be slow on large files; the access throws `InvalidDataException` for corrupt data. The container is one scan with the id `unified-cloud`. |
| Leica | Computed. The container does not store it, so the first access decodes all of the point data and caches the result, which can be slow on large files; the access throws `InvalidDataException` for corrupt data. A container that assigns its points to its setups has one scan per setup, each with the id and the name of its setup; otherwise the container is one scan with the id `unified-cloud`. |
| FARO | Approximate: the size of the scan grid (rows times columns), not the number of valid returns. For a folder scan it is limited by the size of the data stream. |
| PinPoint | A manifest with a scan position list: declared by the manifest, else derived from the data file, else 0 (not known). A manifest with a data object list: always 0 (not known), so `TotalPointCount` is 0 for such a project. |
| EdgeWise | A `.c3db` database node: the count the database declares. A `.c3ptx` file: computed by walking the cluster headers when the file is opened. |
Expand All @@ -73,7 +73,7 @@ are true when the `.rcs` file was found and false otherwise, without the file be

## Format documents

`E57Document`/`E57Scan`, `RcsScanDocument`/`RcsScan`, `RcpProjectDocument`/`RcpScan`, `LgsxDocument`/`LgsxScan`/`LgsxEntry`,
`E57Document`/`E57Scan`, `RcsScanDocument`/`RcsScan`, `RcpProjectDocument`/`RcpScan`, `LgsxDocument`/`LgsxScan`/`LgsxEntry`/`LgsxSetup`,
`FaroFlsDocument`/`FaroScan`, `PinPointDocument`/`PinPointScan` and `EdgeWiseDocument`/`EdgeWiseScan` are the readers behind
`PclFile.Open`. Each has a static `Open` method and format-specific properties (for example the E57 version or the FARO scanner model).
Their XML documentation states what each reader supports. Prefer `PclFile.Open`, which detects the format and chooses the reader.