92 changes: 92 additions & 0 deletions doc/scapy/layers/automotive.rst
Original file line number Diff line number Diff line change
Expand Up @@ -1081,6 +1081,98 @@ to the Scapy interpreter::

.. image:: ../graphics/animations/animation-scapy-uds3.svg


Single Layer Mode
-----------------

UDS, KWP, OBD, and GMLAN all support a *single layer mode* that makes each
service packet a standalone ``Packet`` rather than a nested sublayer.

**Default (multi-layer) mode**

.. code-block:: python

>>> pkt = UDS() / UDS_DSC(diagnosticSessionType=0x01)
>>> UDS(b'\x10\x01')
<UDS service=DiagnosticSessionControl |<UDS_DSC diagnosticSessionType=defaultSession |>>

**Single layer mode**

To enable before loading a module::

>>> conf.contribs['UDS'] = {'treat-response-pending-as-answer': False,
... 'single_layer_mode': True}
>>> load_contrib('automotive.uds')

To toggle at runtime after loading::

>>> conf.contribs['UDS']['single_layer_mode'] = True
>>> UDS(b'\x10\x01')
<UDS_DSC service=DiagnosticSessionControl diagnosticSessionType=defaultSession |>
>>> bytes(UDS_DSC(diagnosticSessionType=0x01))
b'\x10\x01'
>>> conf.contribs['UDS']['single_layer_mode'] = False # revert to multi-layer mode

The same ``single_layer_mode`` key works for all protocols: replace ``'UDS'``
with ``'KWP'``, ``'OBD'``, or ``'GMLAN'`` as appropriate.

Compatibility Mode
------------------

Scapy allows crafting packets freely, including stacking a service sub-packet
on top of the base protocol layer (e.g. ``UDS()/UDS_DSC()``). When both
``single_layer_mode`` *and* stacking are used together, the ``service`` byte
would normally appear twice in the resulting byte stream – once from the base
layer and once from the sub-packet's own ``service`` ConditionalField.

The **compatibility mode** flag (``compatibility_mode``, default ``True``)
addresses this: when it is enabled and ``single_layer_mode`` is active, the
sub-packet's ``service`` field is automatically **suppressed** whenever the
immediate underlayer is already the matching base-protocol packet.

.. list-table:: Behaviour matrix
:header-rows: 1
:widths: 25 25 50

* - ``single_layer_mode``
- ``compatibility_mode``
- ``UDS()/UDS_DSC()`` byte layout
* - ``False``
- any
- ``service`` (UDS) + ``diagnosticSessionType`` (UDS_DSC)
* - ``True``
- ``True`` *(default)*
- ``service`` (UDS) + ``diagnosticSessionType`` (UDS_DSC) — duplicate suppressed
* - ``True``
- ``False``
- ``service`` (UDS) + ``service`` (UDS_DSC) + ``diagnosticSessionType`` (UDS_DSC)

Example with compatibility mode on (default)::

>>> conf.contribs['UDS']['single_layer_mode'] = True
>>> conf.contribs['UDS']['compatibility_mode'] = True # already the default

>>> # Standalone sub-packet: service field IS present (no UDS underlayer)
>>> bytes(UDS_DSC(diagnosticSessionType=0x01))
b'\x10\x01'

>>> # Stacked: service field in UDS_DSC is suppressed (UDS is the underlayer)
>>> bytes(UDS() / UDS_DSC(diagnosticSessionType=0x01))
b'\x10\x01'

Example with compatibility mode off::

>>> conf.contribs['UDS']['compatibility_mode'] = False

>>> # Stacked: both UDS and UDS_DSC emit a service byte
>>> bytes(UDS() / UDS_DSC(diagnosticSessionType=0x01))
b'\x10\x10\x01'

>>> conf.contribs['UDS']['compatibility_mode'] = True # restore default

The same ``compatibility_mode`` key works for all protocols: replace ``'UDS'``
with ``'KWP'``, ``'OBD'``, or ``'GMLAN'`` as appropriate.

GMLAN
=====

Expand Down
Loading
Loading