Skip to content

Fix GLC at low inlet concentration, validation and units - #24

Merged
milanofthe merged 3 commits into
masterfrom
fix/glc-issue-22
Nov 10, 2026
Merged

milanofthe merged 3 commits into
masterfrom
fix/glc-issue-22

Conversation

@milanofthe

Copy link
Copy Markdown
Member

Fixes #22.

  • Gas phase scaled by the equilibrium ratio (w = y_T2 / nu), so all states are of order one at any inlet concentration.
  • Gas-limited regime (k >= 1e3, k ~ 1/c_T_in): closed-form leading-order limit for both BCs, agreeing with the solve to 3.2/k. A tritium-free inlet gives zero exactly.
  • Initial mesh graded towards the gas inlet and outlet layers, and a lower bound on the scaled gas inlet, which removes the square-root singularity at a T2-free inlet under O-C.
  • g argument used (from steps-re), flow_g documented as molar flow, parameter and input validation, NaN passed through.
  • Requires pathsim 0.30.3 (cold restart after a failed warm start, graded initial mesh).

@milanofthe
milanofthe merged commit 6255ad1 into master Nov 10, 2026
5 checks passed
@milanofthe
milanofthe deleted the fix/glc-issue-22 branch November 10, 2026 09:02