S7CommPlusDriver

NuGet NuGet downloads Build Release License

Production-oriented .NET communication library for Siemens S7-1200/1500 PLCs using S7CommPlus over TLS, with legacy challenge authentication available for pre-V17/pre-TLS CPUs on .NET Framework 4.8, net8.0, and net9.0. The package targets net48, net6.0, net8.0, and net9.0.

The supported high-level API for new applications is S7CommPlusClient. Lower-level protocol and transport types remain available for compatibility and diagnostics, but production code should use the client surface.

Acknowledgements

Legacy challenge authentication on net48, net8.0, and net9.0 uses the MIT-licensed HarpoS7 project through the HarpoS7 and HarpoS7.PublicKeys NuGet packages. HarpoS7 provides the challenge, public-key, and packet-digest primitives; S7CommPlusDriver provides the PLC transport, session handling, request ordering, reconnect behavior, and write protection.

What The Production Client Provides

  • Async connect, disconnect, browse, bulk symbol resolution, read, write, active-alarm, subscription, block and symbol-comment metadata, CPU metadata/control, online block-view, and legitimation methods
  • Serialized request execution for safe concurrent callers
  • Typed exceptions with PLC endpoint, operation, error code, and transient/non-transient classification
  • Connection-state and communication-error events
  • Read/browse reconnect retry support
  • Explicit write enablement so accidental PLC writes are blocked by default
  • Bounded disconnect behavior and better socket disconnect detection
  • TLS and legacy S7CommPlus challenge authentication modes
  • No library writes to Console

Requirements

PLC / CPU

The net48/net8.0/net9.0 default first tries secure PG/HMI communication over TLS and, if the PLC rejects it, reconnects with legacy challenge authentication:

  • S7-1200 firmware V4.3 or newer, TLS 1.3 from V4.5
  • S7-1500 firmware V2.9 or newer
  • Software controllers supported by the upstream protocol implementation

For TLS, the PLC project must be configured with a TIA Portal version that supports secure communication, typically TIA Portal V17 or newer. Legacy challenge mode is intended for older projects and CPUs without that TLS configuration.

For older S7-1200/1500 CPUs that do not support TLS, the default Auto mode on net48/net8.0/net9.0 falls back to legacy authentication. Set S7CommPlusSecurityMode.LegacyChallenge to skip the initial TLS attempt. Legacy mode uses HarpoS7-derived challenge authentication and packet digests. net6.0 builds remain TLS-only and fail fast if legacy mode is requested.

TLS Backend

TLS communication uses the managed BouncyCastle backend by default. The older OpenSSL backend remains available through S7CommPlusClientOptions.TlsBackend = S7CommPlusTlsBackend.OpenSsl, but it depends on native runtime files and may be less portable across PLC firmware/OpenSSL combinations.

The package includes native OpenSSL runtime files for Windows x86, x64, and ARM64, plus macOS ARM64. Its build target preserves those runtime-specific assets in the application output. If you select the OpenSSL backend on another platform, compatible OpenSSL 3 native libraries must be available to the process.

Windows runtime files include:

  • libcrypto-3.dll / libssl-3.dll for x86
  • libcrypto-3-x64.dll / libssl-3-x64.dll for x64
  • libcrypto-3-arm64.dll / libssl-3-arm64.dll plus vcruntime140.dll for ARM64

Installation

Install the package from NuGet:

dotnet add package DotNetProjects.S7CommPlusDriver

Quick Start

Create one S7CommPlusClient per PLC endpoint and reuse it for reads. The client serializes operations internally, so multiple callers can safely share the same instance.

await using var client = new S7CommPlusClient(new S7CommPlusClientOptions
{
    Address = "10.0.110.120",
    RequestTimeout = TimeSpan.FromSeconds(5),
    AutoReconnect = true
});

client.ConnectionStateChanged += (_, e) =>
{
    Console.WriteLine($"{e.OldState} -> {e.NewState}");
};

client.CommunicationError += (_, e) =>
{
    Console.WriteLine($"{e.Exception.Operation}: 0x{e.Exception.ErrorCode:X8}");
};

await client.ConnectAsync();

var cpuInfo = await client.GetCpuInfoAsync();
var cpuCulture = await client.GetCpuCultureInfoAsync();
var variables = await client.BrowseAsync();

var tag = await client.GetTagBySymbolAsync("MyDb.MyValue");
var read = await client.ReadAsync(new[] { tag });

if (read.Items[0].IsSuccess)
{
    Console.WriteLine(tag.ToString());
}

await client.DisconnectAsync();

Per-operation timeouts

RequestTimeout remains the default for ordinary requests, while browse APIs use BrowseTimeout. The effective timeout now governs the complete client operation, each protocol response wait, and the connected socket receive/send deadlines. This is important for large symbol catalogs, where a long outer browse deadline alone cannot prevent a shorter protocol wait from failing first.

Use ExecuteWithTimeoutAsync when one call needs a different deadline without changing later requests or creating another client:

var resolvedTags = await client.ExecuteWithTimeoutAsync(
    TimeSpan.FromMinutes(2),
    cancellationToken => client.GetTagsBySymbolsAsync(symbols, cancellationToken),
    cancellationToken);

The override is isolated to the current asynchronous execution context. Concurrent callers can choose different timeouts, and the configured RequestTimeout is restored after each request. Connect, disconnect, and subscription-notification waits retain their dedicated timeout settings.

GetCpuCultureInfoAsync() reads the CPU text-container LCIDs and exposes both the raw language IDs and resolved .NET cultures:

foreach (var culture in cpuCulture.Cultures)
{
    Console.WriteLine($"{culture.LCID}: {culture.Name}");
}

Browsing arrays

BrowseAsync() returns primitive arrays as one VarInfo by default. Use ArrayElementCount and ArrayDimensions to inspect the PLC bounds without creating one browse item for every byte, Boolean, or other primitive element:

foreach (var variable in await client.BrowseAsync())
{
    if (variable.ArrayElementCount > 0)
    {
        Console.WriteLine($"{variable.Name}: {variable.ArrayElementCount} elements");
    }
}

Applications that require the former flattened representation can request it explicitly:

var elements = await client.BrowseAsync(new S7CommPlusBrowseOptions
{
    ExpandPrimitiveArrayElements = true
});

Arrays of structures are always traversed because their readable member fields cannot be represented by one primitive value.

String, Date_And_Time, and packed DTL arrays can be resolved and read both as complete arrays and as indexed elements. The client expands these requests into scalar wire addresses when the PLC does not accept the declaration address; PlcTagDTLArray exposes the flattened Value, ValueNanosecond, and DTLInterfaceTimestamps arrays.

Resolving many symbols efficiently

Use GetTagsBySymbolsAsync to resolve a large configured tag set with one PLC catalog browse. The result is a case-sensitive dictionary; symbols not found in the current PLC program are omitted. Fully indexed primitive-array symbols are resolved from the aggregate array metadata, including non-zero lower bounds and multidimensional arrays:

var symbols = new[]
{
    "MyDb.MyValue",
    "MyDb.Payload[3]",
    "MyDb.Matrix[1,2]"
};

var tagsBySymbol = await client.GetTagsBySymbolsAsync(symbols);
var read = await client.ReadAsync(tagsBySymbol.Values);

The client retains this symbol catalog across reconnects. When the PLC program structure changes, invalidate it before rebuilding application tag caches:

await client.InvalidateSymbolCatalogAsync();
var refreshedTags = await client.GetTagsBySymbolsAsync(symbols);

Applications that know their complete configured symbol set can avoid retaining the full PLC catalog. Read and verify the program hash first, then create a compact accessor catalog whose entries contain only the datatype and wire addresses required by those symbols:

var structure = await client.GetPlcStructureXmlAsync();
var accessors = await client.CreateTagAccessorCatalogAsync(
    symbols,
    structure.ProgramChangeMarker.StructureHash);
var tags = accessors.CreateTags(symbols);

The compact catalog also records requested symbols that were not present, so CoversSymbols can distinguish a known-missing tag from a tag added after the catalog was built. It can be persisted without retaining VarInfo objects:

await using (var output = File.Create(cachePath))
{
    accessors.WriteTo(output);
}

await using var input = File.OpenRead(cachePath);
var cachedAccessors = S7CommPlusTagAccessorCatalog.ReadFrom(
    input,
    structure.ProgramChangeMarker.StructureHash);

ReadFrom rejects malformed files, unsupported format versions, and program hash mismatches. Each CreateTags call returns an independent set of mutable PlcTag objects. If an application already has the matching BrowseAsync result, S7CommPlusClient.CreateTagAccessorCatalog creates the same compact catalog locally without another PLC request.

The built-in connection defaults match Siemens S7CommPlus HMI communication: ISO-on-TCP port S7CommPlusDefaults.IsoTcpPort (102), local TSAP S7CommPlusDefaults.LocalTsap (0x0600), and remote TSAP S7CommPlusDefaults.RemoteTsapHmi (SIMATIC-ROOT-HMI). Project/engineering captures sometimes use S7CommPlusDefaults.RemoteTsapEs (SIMATIC-ROOT-ES). Remote TSAP values are validated as ASCII COTP parameters before a socket is opened.

CPU Runtime Status and Control

The client exposes the CPU operating state, scan-cycle measurements, and memory usage in addition to the general CPU information and culture catalog:

var state = await client.GetCpuStateAsync();
var cycleTime = await client.GetCpuCycleTimeAsync();
var memory = await client.GetCpuMemoryUsageAsync();

Console.WriteLine($"{state.OperatingState}: {cycleTime.CurrentMilliseconds} ms");

StartCpuAsync and StopCpuAsync change PLC state, so they use the same safety gate as tag writes and require WriteEnabled = true. They are never retried automatically.

Password Legitimation

Initial session authentication and PLC password legitimation are separate steps. If the PLC requires a password for the desired access level, either pass credentials in the options so they are used during connect, or call LegitimateAsync after connecting:

await using var client = new S7CommPlusClient(new S7CommPlusClientOptions
{
    Address = "10.0.110.120",
    Password = "plc-password"
});

await client.ConnectAsync();

// Or, for an already connected session:
await client.LegitimateAsync("plc-password", username: "");

Legitimation is a session-security operation, not a PLC signal write, so it does not require WriteEnabled = true. Failed legitimation attempts throw S7CommPlusLegitimationException.

Active Alarms

Active alarms are exposed through the same serialized read pipeline and can therefore use the normal timeout, reconnect, logging, and typed-error behavior:

var alarms = await client.GetActiveAlarmsAsync(languageId: 1033);

Use this call to get alarms that are already active when your application connects. Alarm subscriptions report new notification frames on that session; they should not be used as the only source for pre-existing alarms.

Each S7CommPlusAlarm exposes the decoded identity parts from CpuAlarmId: SourceRelationId and SourceAlarmId. For PLC program alarms, SourceRelationId is the PLC object relation id encoded into the alarm id; a higher-level project/catalog API can map it to a block name or call path.

PLC Text Lists and Alarm Text Formatting

PLC alarm texts can contain TIA-style text-list placeholders such as @2%t#519K@. Load the PLC text-list catalog once and pass it to the alarm APIs when you want those placeholders expanded with the same text lists that are stored in the CPU:

var textLists = await client.GetTextListsAsync();
var alarms = await client.GetActiveAlarmsAsync(languageId: 1031, textLists);

foreach (var alarm in alarms)
{
    Console.WriteLine(alarm.AlarmTexts?.AlarmText);
}

GetTextListsAsync() discovers the CPU languages from the PLC text container and loads all available localized text-list libraries, plus the language-independent system text-list library. To load only selected languages, pass LCIDs explicitly:

var textLists = await client.GetTextListsAsync(new[] { 1031, 2057 });

The catalog remains a single API surface, but each S7CommPlusTextList exposes TextListType so callers can distinguish runtime user lists from system lists:

var userLists = textLists.TextLists
    .Where(list => list.TextListType == S7CommPlusTextListType.User);

var systemLists = textLists.TextLists
    .Where(list => list.TextListType == S7CommPlusTextListType.System);

The online PLC payload does not expose the full engineering project object kind, so the driver classifies text lists by Siemens runtime list-id conventions. The catalog resolver still uses all lists, because system diagnostic texts and user alarm texts can reference each other recursively.

Associated-value placeholders are formatted as well. For example, @2W%d@ uses the second associated value as a WORD and formats it as signed decimal, matching TIA's standard element-type syntax.

Communication Limits

PLC communication limits are available through the production client. This is useful before creating subscriptions or planning large batch reads:

var resources = await client.GetCommunicationResourcesAsync();

Console.WriteLine(resources.TagsPerReadRequestMax);
Console.WriteLine(resources.PlcSubscriptionsFree);

Block Metadata and Online View

The production client can browse block metadata, parse the PLC structure XML into a block tree, read block content, and open TIA-style block online-view subscriptions:

var blocks = await client.BrowseBlocksAsync();
var structure = await client.BrowseBlockStructureAsync();
var content = await client.GetBlockContentAsync(blocks[0].RelationId);

Localized engineering comments can be loaded independently of block code. The returned catalog maps a browsed VarInfo to all comments supplied by the PLC, keyed by Windows locale identifier (LCID):

var comments = await client.GetSymbolCommentsAsync(blocks[0].RelationId);

foreach (var variable in await client.BrowseAsync())
{
    if (comments.TryGetComments(variable, out var localized))
    {
        Console.WriteLine($"{variable.Name}: {localized.GetValueOrDefault(1033)}");
    }
}

Cache one S7CommPlusSymbolCommentCatalog per block or absolute I/Q/M relation ID while processing a browse. Array indices are normalized to the declaration comment for data-block symbols; absolute-area access sequences remain exact.

OpenBlockOnlineViewAsync creates a disposable S7CommPlusTisWatchSubscription for advanced block-watch scenarios. This API is lower level than tag reads and requires a caller-provided S7CommPlusTisWatchRequest that matches the block watch points and result model.

Subscriptions

Subscriptions are exposed as long-running, disposable objects. Notification frames arrive on the same PLC session as normal request/response traffic, and the client serializes foreground requests while routing notifications by PLC subscription object ID.

var tag = await client.GetTagBySymbolAsync("MyDb.MyValue");

await using var subscription = await client.SubscribeTagsAsync(
    new[] { tag },
    new S7CommPlusSubscriptionOptions
    {
        CycleTimeMilliseconds = 250,
        NotificationTimeout = TimeSpan.FromSeconds(5)
    });

subscription.NotificationReceived += (_, e) =>
{
    foreach (var item in e.Notification.Items)
    {
        if (item.IsSuccess)
        {
            Console.WriteLine(item.Tag);
        }
    }
};

subscription.CommunicationError += (_, e) =>
{
    Console.WriteLine($"{e.Exception.Operation}: 0x{e.Exception.ErrorCode:X8}");
};

Alarm notifications use the same lifecycle and credit handling:

await using var snapshotClient = new S7CommPlusClient(options);
var textLists = await client.GetTextListsAsync(new[] { 1033 });
await using var alarmSession = await client.SubscribeAlarmsWithSnapshotAsync(snapshotClient, 1033, textLists);

foreach (var activeAlarm in alarmSession.ActiveAlarms)
{
    Console.WriteLine(activeAlarm.AlarmTexts?.AlarmText);
}

alarmSession.Subscription.NotificationReceived += (_, e) =>
{
    foreach (var alarm in e.Notification.Alarms)
    {
        Console.WriteLine(alarm.ToString());
    }
};

Subscriptions can share one S7CommPlusClient with reads, metadata calls, and other subscriptions. The client keeps one foreground request in flight per physical PLC connection and routes notifications by PLC subscription object id. Use a second client only when you explicitly want a second physical PLC connection, for example for true parallel large metadata transfers.

SubscribeAlarmsAsync() without a language id reads the CPU language catalog and explicitly requests its first three languages, avoiding PLCs that reject an empty all-language subscription filter. GetActiveAlarmsAsync() without a language id still requests every language returned by the PLC. The compatibility AlarmTexts property contains the selected or first CPU language, while AlarmTextsByLanguage contains every language returned for that request.

Alarm snapshots require explicit connection ownership: create another S7CommPlusClient and pass it to SubscribeAlarmsWithSnapshotAsync when you want a live alarm subscription plus an initial active-alarm snapshot on a separate physical connection. Stopping an alarm subscription deletes only that subscription and keeps the client session available for later requests.

Idle notification waits are not treated as failures by default. Set MaxConsecutiveTimeoutsBeforeFault when a quiet subscription should become a typed communication failure after a fixed number of empty waits. Write protection is unchanged: subscriptions do not enable PLC signal writes.

Older PLCs / Legacy Challenge Auth

On net48/net8.0/net9.0, Auto is the default: it tries TLS first and reconnects with the older Siemens challenge authentication when TLS is rejected. Applications that must never downgrade should explicitly set SecurityMode to Tls. To force legacy mode and skip the initial TLS attempt:

await using var client = new S7CommPlusClient(new S7CommPlusClientOptions
{
    Address = "10.0.110.120",
    SecurityMode = S7CommPlusSecurityMode.LegacyChallenge,
    RequestTimeout = TimeSpan.FromSeconds(5)
});

await client.ConnectAsync();
Console.WriteLine(client.Options.NegotiatedSecurityMode);

S7CommPlusSecurityMode.Auto tries TLS first and then falls back to legacy challenge authentication. net6.0 remains TLS-only. Reconnect and write safety behave the same in all modes: read/browse may reconnect once, writes are never retried automatically, and writes still require WriteEnabled = true.

Legacy integrity keys expire even when requests are still flowing; normal reads do not reset that lifetime. The driver therefore renews a legacy session key every 25 minutes by default, before the roughly 30-minute renewal point observed in TIA Portal traffic. Configure this with LegacySessionKeyRefreshEnabled and LegacySessionKeyRefreshInterval. Renewal is an internal session-control exchange and does not write PLC tags or require WriteEnabled = true.

See Acknowledgements for the HarpoS7 dependency and attribution. This project remains LGPL-3.0-or-later unless noted otherwise.

Recent legacy auth work parses ServerSessionVersion from the CreateObject response where available, so S7-1500 V3.x authentication-frame selection is response-driven before falling back to capture-compatible heuristics.

Write Safety

Writes are disabled by default. This is intentional for production services and tests.

await using var client = new S7CommPlusClient(new S7CommPlusClientOptions
{
    Address = "10.0.110.120",
    WriteEnabled = true
});

await client.ConnectAsync();
await client.WriteAsync(new[] { tag });

If WriteEnabled is false, write calls throw S7CommPlusWriteDisabledException.

Error Handling

Operations throw S7CommPlusException subclasses instead of returning only integer error codes. The exception includes:

  • Operation
  • Endpoint
  • ErrorCode
  • IsTransient

Read and browse operations retry once after a transient communication failure when AutoReconnect is enabled. Writes are not retried automatically.

Logging And Diagnostics

S7CommPlusClientOptions.Logger accepts an ILogger. If no logger is provided, NullLogger is used.

The library no longer writes diagnostics to Console. Lower-level diagnostics are written via System.Diagnostics.Trace.

TLS key logging for Wireshark analysis is still available through the low-level S7Client.WriteSslKeyToFile and S7Client.WriteSslKeyPath settings. Use this only in controlled diagnostic environments.

Testing

Run the normal build and unit tests:

dotnet build src\S7CommPlusDriver.slnx /nodeReuse:false
dotnet test src\S7CommPlusDriver.Tests\S7CommPlusDriver.Tests.csproj --no-restore /nodeReuse:false

The live PLC smoke test is opt-in and read-only by default:

$env:S7COMMPLUS_LIVE_HOST = "10.0.110.120"
dotnet test src\S7CommPlusDriver.Tests\S7CommPlusDriver.Tests.csproj --filter LivePlcReadOnlySmokeTest

By default the live test connects, reads CPU and culture information, loads PLC text lists, browses, and disconnects. To read explicit tags, provide semicolon-separated tag symbols:

$env:S7COMMPLUS_LIVE_TAGS = "MyDb.MyValue;OtherDb.Counter"

To exercise legacy auth or auto fallback in the live test:

$env:S7COMMPLUS_LIVE_SECURITY_MODE = "LegacyChallenge" # or "Auto"

TLS backend and timeout overrides are also available when validating a specific configuration:

$env:S7COMMPLUS_LIVE_TLS_BACKEND = "BouncyCastle" # or "OpenSsl"
$env:S7COMMPLUS_LIVE_REQUEST_TIMEOUT_SECONDS = "15"
$env:S7COMMPLUS_LIVE_CONNECT_TIMEOUT_SECONDS = "10"

Never use the live smoke test for writes.

Tested Communication

Known tested targets include:

  • S7 1211 firmware V4.5
  • TIA PLCSIM V17 with NetToPLCSim
  • TIA PLCSIM V18 with NetToPLCSim
  • read-only smoke test against a real PLC at 10.0.110.120

Supported Data Types

The PlcTag classes convert PLC values into .NET-friendly types. Supported data types include scalar and array variants for common Siemens types such as Bool, Byte, Word, Int, DInt, Real, LReal, String, WString, Date, Date_And_Time, DTL, Time, LTime, pointer-like types, hardware identifiers, counters, and timers.

For exact mappings, see the implementations in src/S7CommPlusDriver/ClientApi/PlcTag.cs and src/S7CommPlusDriver/ClientApi/PlcTags.cs.

License

Unless otherwise noted, all source code is licensed under LGPL-3.0-or-later.