Summary

  • restore the prominent R730xd / iDRAC 8-only hardware disclaimer in both READMEs
  • reject source temperatures outside -20..150 C before fan decisions
  • restore Dell automatic control when manual mode succeeds but the duty-cycle command fails
  • add regression coverage for both safety paths

Field finding

A TrueNAS VM saw a VMware virtual NVMe SMART temperature of 11759 C. The prior controller accepted it and continuously selected the critical fan level. This patch treats such numeric-but-invalid telemetry as a failed reading, allowing other valid sources or the configured fail-safe to decide.

Verification

  • make test: 60 core assertions, 14 TUI assertions
  • git diff --check