Manual Test Plan - PR-5 TCP Monitor UX Fix

Scope

PR-5 only.

This plan covers manual verification of the five UX fixes applied to the TCP monitor creation form:

  1. Corrected URL placeholder (removed misleading tcp:// prefix)
  2. Dynamic per-type placeholder (HTTP vs TCP)
  3. Per-type helper text below the URL input
  4. Client-side TCP scheme validation with inline error
  5. Form field reorder: type selector now appears before URL input

Out of scope:

  • Backend monitor logic or storage
  • Any other monitor type beyond HTTP and TCP
  • Notification provider changes

Preconditions

  • Environment is running (Docker E2E or local dev).
  • Tester can access the Monitors page and open the Create Monitor modal.
  • Browser DevTools Network tab is available for TC-PR5-007.

Track A — Smoke Tests (Existing HTTP Behaviour)

TC-PR5-001 HTTP monitor creation still works

  • Open the Create Monitor modal.
  • Select type HTTP.
  • Enter a valid URL: https://example.com.
  • Fill in remaining required fields and click Create.
  • Expected result: monitor is created successfully; no errors shown.
  • Status: [ ] Not run [ ] Pass [ ] Fail
  • Notes:

TC-PR5-009 Existing HTTP monitors display correctly in the list

  • Navigate to the Monitors list.
  • Confirm any pre-existing HTTP monitors are still shown with correct URLs.
  • Expected result: no regressions in list display.
  • Status: [ ] Not run [ ] Pass [ ] Fail
  • Notes:

TC-PR5-010 Existing TCP monitors display correctly in the list

  • Navigate to the Monitors list.
  • Confirm any pre-existing TCP monitors are still shown with correct host:port values.
  • Expected result: no regressions in list display.
  • Status: [ ] Not run [ ] Pass [ ] Fail
  • Notes:

Track B — Core Fix (TCP Scheme Validation)

TC-PR5-002 TCP monitor with tcp:// prefix shows inline error and blocks submission

  • Open the Create Monitor modal.
  • Select type TCP.
  • Enter URL: tcp://192.168.1.1:8080.
  • Click Create (or attempt to submit).
  • Expected result: an inline error appears on the URL field; the form is not submitted; no new monitor appears in the list.
  • Status: [ ] Not run [ ] Pass [ ] Fail
  • Notes:

TC-PR5-003 TCP monitor with valid host:port format succeeds

  • Open the Create Monitor modal.
  • Select type TCP.
  • Enter URL: 192.168.1.1:8080.
  • Fill in remaining required fields and click Create.
  • Expected result: monitor is created successfully; no errors shown.
  • Status: [ ] Not run [ ] Pass [ ] Fail
  • Notes:

Track C — Dynamic Placeholder & Helper Text

TC-PR5-005 Form field order: Type selector appears above URL input

  • Open the Create Monitor modal.
  • Inspect the visual layout of the form.
  • Expected result: the monitor Type selector is positioned above the URL input field.
  • Status: [ ] Not run [ ] Pass [ ] Fail
  • Notes:

TC-PR5-006 Helper text updates when switching between HTTP and TCP

  • Open the Create Monitor modal.
  • Select type HTTP and note the helper text shown beneath the URL input.
  • Switch type to TCP and note the helper text again.
  • Expected result: helper text differs between HTTP and TCP types, giving format guidance appropriate to each.
  • Status: [ ] Not run [ ] Pass [ ] Fail
  • Notes:

TC-PR5-006b Placeholder updates when switching between HTTP and TCP

  • Open the Create Monitor modal.
  • Select type HTTP and note the URL input placeholder.
  • Switch type to TCP and note the placeholder again.
  • Expected result: HTTP placeholder shows a full URL (e.g. https://example.com); TCP placeholder shows host:port format (no scheme).
  • Status: [ ] Not run [ ] Pass [ ] Fail
  • Notes:

Track D — Interaction Edge Cases

TC-PR5-004 Switching type from TCP (with error) to HTTP clears the inline error

  • Open the Create Monitor modal.
  • Select type TCP and enter tcp://192.168.1.1:8080 to trigger the inline error.
  • Switch type to HTTP.
  • Expected result: the scheme-prefix inline error disappears immediately after the type change.
  • Status: [ ] Not run [ ] Pass [ ] Fail
  • Notes:

TC-PR5-007 Submit guard: no API call fires when scheme prefix error is present

  • Open browser DevTools and go to the Network tab.
  • Open the Create Monitor modal.
  • Select type TCP and enter tcp://192.168.1.1:8080.
  • Click Create.
  • Expected result: the inline error is shown and no outbound POST/PUT request to the monitors API endpoint appears in the Network tab.
  • Status: [ ] Not run [ ] Pass [ ] Fail
  • Notes:

Track E — Localisation (Optional)

TC-PR5-008 New translation keys appear correctly in non-English locales

  • Switch the application language to German, French, Spanish, or Chinese.
  • Open the Create Monitor modal and select type TCP.
  • Observe the URL placeholder, helper text, and inline error message (trigger it with tcp://host:port).
  • Expected result: all three UI strings appear in the selected language without showing raw translation key strings (e.g. no urlPlaceholder.tcp visible to the user).
  • Status: [ ] Not run [ ] Pass [ ] Fail
  • Notes:

Sign-off

Tester Date Environment Result

Auto-created from pr5-tcp-monitor-ux-manual-test.md

Metadata

Metadata

Assignees

No one assigned

    Labels

    bugSomething isn't workingfrontendUI/UX codehighImportant feature, should be includedtestingTest suite

    Projects

    Status

    Backlog

    Milestone

    No milestone

    Relationships

    None yet

    Development

    No branches or pull requests

    Issue actions