From 4e92d3f407df50ddda17bc9e49e2b1fd89f1b53e Mon Sep 17 00:00:00 2001 From: MD Danish Anwar Date: Tue, 3 Nov 2026 14:45:29 +0530 Subject: [PATCH] fix(CPSW-EST): fix cycle time unit typo in EST configuration example Correct the cycle time unit in the EST documentation from 500 msec to 500 usecs (microseconds). The Gate Control List (GCL) defines three entries with intervals of 125000 ns, 125000 ns, and 250000 ns. The sum of these intervals is 500,000 nanoseconds, which evaluates exactly to 500 microseconds (0.5 milliseconds), not 500 milliseconds. Signed-off-by: MD Danish Anwar --- .../Kernel/Kernel_Drivers/Network/CPSW-EST.rst | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/source/linux/Foundational_Components/Kernel/Kernel_Drivers/Network/CPSW-EST.rst b/source/linux/Foundational_Components/Kernel/Kernel_Drivers/Network/CPSW-EST.rst index 9a923a038..dec66fad4 100644 --- a/source/linux/Foundational_Components/Kernel/Kernel_Drivers/Network/CPSW-EST.rst +++ b/source/linux/Foundational_Components/Kernel/Kernel_Drivers/Network/CPSW-EST.rst @@ -66,7 +66,7 @@ Here are the steps to configure this schedule. # S - SetGateStates operation # 4 - Bit mask showing bit 2 set (Q2/TC2) # 125000 - 125000 nsecs (125 usecs ) duration of Gate open - # The cycle-time is 500 msec + # The cycle-time is 500 usecs #enable classifier. Classifier is used to mark the packet based on packet meta data. For example UDP port #number